출처 : http://web.bii.a-star.edu.sg/~james/100TB/14TB/faults/2007-03-05.html


Fault Log : 5th Mar 2007
Description : Disk warning on storage node 1, port 1

One of the drives on storage node 1 developed a hardware fault which was detected by automated scripts. A notification email was sent from the management node at 19:38 today. The following message was observed in storage node 1's /var/log/messages :

    Mar 5 19:28:21 linux kernel: [12972720.367977] 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0009): Drive timeout detected:port=1.

The following command shows the drive error :

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    OK*            -      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      WARNING        -      p1    -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

# smartctl -a -d 3ware,1 /dev/twa0

smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     HDS725050KLA360
Serial Number:    KRVN03ZAHRS7BD
Firmware Version: K2AOAB0A
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1
Local Time is:    Thu Mar  8 13:04:40 2007 SGT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (10419) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 174) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0007   106   106   024    Pre-fail  Always       -       655 (Average 655)
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       41
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       2
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       3826
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       41
192 Power-Off_Retract_Count 0x0032   100   100   050    Old_age   Always       -       195
193 Load_Cycle_Count        0x0012   100   100   050    Old_age   Always       -       195
194 Temperature_Celsius     0x0002   171   171   000    Old_age   Always       -       32 (Lifetime Min/Max 18/36)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       2
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

It appears that the 3ware card has not marked the disk as "failed", since the RAID5 array was not considered degraded. I would like to force the controller to rebuild the disk, by "removing" and "reinserting" the disk. However, since a hotspare was already assigned, I would have to delete the hotspare drive first.

# ./tw_cli maint deleteunit c0 u1
Deleting unit c0/u1 ...Done.

# ./tw_cli maint remove c0 p1
Exporting port /c0/p1 ... Done.

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    DEGRADED       -      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      DEGRADED       -      -     -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

# ./tw_cli maint rescan c0
Rescanning controller /c0 for units and drives ...Done.
Found the following unit(s): [none].
Found the following drive(s): [/c0/p1].

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    REBUILDING     0      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      DEGRADED       -      p15   -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

It was then that I realized that despite removing the hotspare drive, the 3ware card had decided to use the disk on p15 for rebuilding the RAID5 volume. Thus, I had to perform another "removal" of the drive on p15, to force the 3ware in to using p1 for rebuilding. Note that there was a time delay of a few minutes before the 3ware decided to commence rebuilding on p1 (ie, DEGRADED -> REBUILD-PAUSED -> REBUILDING).

# ./tw_cli maint remove c0 p15
Exporting port /c0/p15 ... Done.

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    DEGRADED       -      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      DEGRADED       -      -     -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    REBUILD-PAUSED 0      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      DEGRADED       -      p1    -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

# ./tw_cli /c0/u0 show

Unit     UnitType  Status         %Cmpl  Port  Stripe  Size(GB)  Blocks
-----------------------------------------------------------------------
u0       RAID-5    REBUILDING     0      -     64K     6519.12   13671583744 
u0-0     DISK      OK             -      p0    -       465.651   976541696   
u0-1     DISK      DEGRADED       -      p1    -       465.651   976541696   
u0-2     DISK      OK             -      p2    -       465.651   976541696   
u0-3     DISK      OK             -      p3    -       465.651   976541696   
u0-4     DISK      OK             -      p4    -       465.651   976541696   
u0-5     DISK      OK             -      p5    -       465.651   976541696   
u0-6     DISK      OK             -      p6    -       465.651   976541696   
u0-7     DISK      OK             -      p7    -       465.651   976541696   
u0-8     DISK      OK             -      p8    -       465.651   976541696   
u0-9     DISK      OK             -      p9    -       465.651   976541696   
u0-10    DISK      OK             -      p10   -       465.651   976541696   
u0-11    DISK      OK             -      p11   -       465.651   976541696   
u0-12    DISK      OK             -      p12   -       465.651   976541696   
u0-13    DISK      OK             -      p13   -       465.651   976541696   
u0-14    DISK      OK             -      p14   -       465.651   976541696   
u0/v0    Volume    -              -      -     -       6519.12   13671583744 

Finally, I redesignate p15 as the hotspare.

# ./tw_cli maint rescan c0
Rescanning controller /c0 for units and drives ...Done.
Found the following unit(s): [none].
Found the following drive(s): [/c0/p15].

# ./tw_cli maint createunit c0 rspare p15
Creating new unit on controller /c0 ...  Done. The new unit is /c0/u1.

The following entries were found in /var/log/messages. They correspond to the actions mentioned above.

Mar  8 13:15:47 linux kernel: [13209543.278994] 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit:unit=0, port=1.
Mar  8 13:17:05 linux kernel: [13209621.293550] 3w-9xxx: scsi0: AEN: INFO (0x04:0x001A): Drive inserted:port=1.
Mar  8 13:17:09 linux kernel: [13209625.704754] 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0.
Mar  8 13:22:51 linux kernel: [13209968.144051] 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit:unit=0, port=15.
Mar  8 13:25:39 linux kernel: [13210135.641076] 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0.
Mar  8 13:29:22 linux kernel: [13210358.314647] 3w-9xxx: scsi0: AEN: INFO (0x04:0x001A): Drive inserted:port=15.
Mar  8 18:02:41 linux kernel: [13226756.373219] 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Rebuild completed:unit=0.